1. INTRODUCTION

Energy storage in the electrical system consists of the accumulation of a certain amount of energy, produced at a given time, in order to be able to use it at a later time of need, both as final energy and as energy to be converted into another carrier.

Energy storage offers many opportunities in the residential as well as in the distribution sector. It namely allows:

  • to import and/or store energy when the price is lower, feeding it into the electricity grid when necessary or when the cost of energy increases;
  • to provide ancillary services, such as frequency response or voltage control;
  • in the vicinity of renewable energy plants, to store energy at times of overproduction and/or falling demand, feeding it into the electricity grid at times of peak or falling production.

2. ENERGY STORAGE SYSTEMS

Energy storage takes place through storage systems of various kinds, exploiting the various forms of mechanical, thermal, electrochemical, potential of a system to make available thermal or electrical energy at times when generating it is not possible (i.e. to compensate for inactivity of wind farms for lack of wind) or is less cost-effective:

Mechanical Hydric pumping
Compressed air
Flywheel
Elettrochemical Flow batteries
Rechargable batteries
Chemical Hydrogen and Power-to-gas
Electrical double layer capacitors
magnetic superconductors
Thermal -

In particular, electrical storage systems are used in 3 main sectors:

  • Consumer electronic equipment;
  • Electric mobility;
  • Support for the electrical network and isolated or microgrid systems.

For this latter application, the main functions offered are:

  • Compensation of generation undercapacity by non-programmable renewable sources;
  • Management of weekly/seasonal fluctuations;
  • Grid balancing regulation services;
  • Peak shaving1.

2.1 ENERGY STORAGE SYSTEMS AND RENEWABLE ENERGY SOURCES

Storage systems represent an added value in the field of energy production from Renewable Energy Sources ("RES"). Beside of that, when talking about RES energy systems some of their specificities shall be also considered.

The first is that, for many of them such as wind and solar, the non-accumulation in the primary form, therefore the variability, the randomness and being dependent site.

These characteristics make them difficult to manage and require compensation systems: therefore, nowadays the focus is on researching and using stationary management storage systems, i.e. fixed and connected to energy networks.

Very often, production from intermittent RES cannot be synchronised with its use. This implies the need to have compensation systems to overcome the time gap between energy production and its use.

Compensation can be carried out by storage systems, able to exchange energy at demand, or perfectly modular production systems of the same energy form, or hybrid systems, accumulation plus generation, very flexible and able to develop a compensation action in real time.

In fact, the electrochemical storage, in the Italian network, is mainly used to integrate RES and to increase flexibility of the network in the perspective of the implementation of smart grids2.

Particularly electrochemical storage has the potential to support the Italian national electricity generation system, but at the moment technological difficulties for replacing fossil fuels are still present and are connected to those characteristics (low accumulation, variability, randomness, dependent site and especially low energy density) that generally lead to plants of not very high power, larger construction dimensions compared to plants with fossil fuels of equal power, a low number of equivalent hours of production to the nominal power and efficiency of transformation of the form of energy not high, and construction costs of plants not at all competitive.

For this reason, although the capacity of storage systems in the world exceeds 125,000 MW, it is actually made up of 98-99% hydroelectric pumping plants.

However, the prospects for technological improvement and cost reduction suggests that other storage systems, and particularly electrochemical systems, will spread rapidly.

According to a report drafted by the Boston Consulting Group, storage systems for electricity generation could rise to 420,000 MW in 2030 and about half could be represented by electrochemical storage systems. This is about 280 billion of cumulative investments.

In Europe, although hydroelectric pumping systems remain the most widespread form of storage on the grid, from 2011 to 2014 other storage systems doubled and reached 1,500 MW:

Source: IEA3

In Italy there are now about 56 MW of electrochemical storage plants, of which 56% is connected to the grid and mostly owned by Terna (50%) and Enel (30%). This is about one hundredth of the hydroelectric storage capacity in the large Italian basins (about 7,000 MW), which, however, have few possibilities for further development since the most suitable sites are already exploited and due to the significant environmental impact of this kind of technology.

In this perspective, the characteristics of flexibility, versatility and modularity make electrochemical storage one of the preferred solutions for the future.

The European Union has recognised the fundamental role of electricity storage for the sustainable development of the European system by including storage among the priority strategic technologies in the sense of the Strategic Energy Technology Plan ("SET Plan"), which sets out energy strategies for 2050.

The industry seems to have well understood the potential of this market and has seen the emergence of several players both for residential applications, particularly in combination with photovoltaic systems (ABB, SMA, Samsung, Tesla, Sonnenbatterie, BYD) and for applications on the grid (Siemens, Samsung, Toshiba, Fiamm, General Electric).

3. THE ITALIAN REGULATORY FRAMEWORK

The Regulatory Authority for Energy, Networks and Environment (hereinafter "ARERA") has defined appropriate provisions aimed at allowing the integration in the Italian network of storage systems, defined as "a set of devices, equipment and management and control logic, functional to absorb and release electrical energy, designed to operate continuously in parallel with the network with the obligation to connect third parties or capable of causing an alteration of the exchange profiles with the electrical network (feed-in and / or withdrawal). Storage systems can be integrated or not with a production plant (if present). This does not include systems used in emergency conditions which, therefore, only come into operation when the power supply is interrupted for reasons beyond the control of the person who has access to them"4.

  • ensure the continuity of the power supply, " provisions for the connection of storage systems to the network;
  • the conditions for the correct grant of incentives or special commercial schemes (dedicated withdrawal and on-site exchange), in case of integration of storage systems in production facilities already aided.
  • improve the quality of the voltage (voltage dips, flicker, harmonics, dissymmetry, rapid variations).

As a result, storage systems do not include those systems which only:

The Authority also stated that storage systems, being capable of exchanging electricity with the network, shall be treated as production plants or, in cases where they are installed at production facilities, as generation groups5.

The current regulatory framework defines:

  • storage systems are treated as generation groups and, depending on the type of plant and the interdependence between the various groups, may or may not constitute a production section;
  • dispatching users, or even producers, to define a specific production unit for the installed storage systems;
  • a production unit characterised by different generation groups, including at least one storage system, is considered a programmable or non-programmable unit depending on the type of the other generation groups.

3.1. CONDITIONS FOR THE INSTALLATION OF STORAGE SYSTEMS

Storage systems must be integrated into the energy network accordingly to the provisions related to connection services, transmission, distribution, measurement and dispatching of electrical energy provided by the resolutions of the Authority, as well as in compliance with the rules of the Italian Electrotechnical Committee ("CEI").

For the purposes of the installation of storage systems, the Integrated Text on Active Connections (hereinafter "TICA"), including the registration on the Management System of the Single Master Data of the Production Plants and related units ("GAUDÌ"), does apply.

In case of storage systems not connected with generation plants, the subject who requests the connection also performs the registration in Terna's GAUDÌ system upon presentation to the competent network operator a request for a new connection, in accordance with the TICA.

If the storage system is combined with production plants, the applicant shall update the master data of the production plant in the GAUDÌ system, entering all the information required for the storage systems, upon presentation to the territorially competent grid operator of a request for adaptation of the existing connection, in accordance with the TICA.

As foreseen by the reference regulation:

3.2 STORAGE SYSTEMS IN AIDED PLANTS

In case of storage systems installed to production plants for which admission to the incentives or special commercial schemes or guarantees of origin is requested, or in case of plants already benefiting from them, for the purposes of recognising and maintaining the incentives, special commercial schemes or guarantees of origin, only the power of the production plant where these systems are installed is considered (net, therefore, of the power of the storage system itself).

However, for photovoltaic systems with a power of up to 20 kW, operating in exchange on site and benefiting from the incentives under the DDMM of 28 July 2005 and 6 February 2006 (first Energy Account), the installation of storage systems is not compatible with the provision of the incentives themselves.

Access or maintenance of the incentives, as well as the benefits provided by the Decrees and Resolutions of reference, is allowed only after the correct installation and activation of the appropriate measuring equipment, if necessary pursuant to Resolution 574/2012/R/eel and TIME6 to quantify the energy produced, the energy fed into the grid and the energy absorbed and released by storage systems, as certified by network operators.

The GSE reserves the right, however, to adopt specific measures for the remuneration of electricity withdrawn by the same GSE and fed into the network. With regards to this, it should be noted that:

  • in case of production-side storage systems, where the equipment for measuring the produced energy is characterised by one-way meters, the person responsible for the operation and maintenance activities of the aforesaid equipment must, by the date of entry into operation of the storage system, replace them with two-way measuring equipment that complies with the TIME;
  • in case of post-production storage systems, for production plants only which have access to all-inclusive tariffs and/or which benefit from the minimum guaranteed prices, the person responsible for operation and maintenance of the electrical energy measurement equipment absorbed and released by an storage system must, by the date of entry into operation of the storage system, install two-way electrical energy measurement equipment absorbed and released by the storage system and, if they are not present, the installation of energy measurement equipment produced, in accordance with TIME.

Footnotes

1. A process by which energy is stored when demand is low and released when demand is high in order to remove peaks.

2. Power grid equipped with intelligent sensors that collect information in real time optimizing the distribution of energy.

3. International Energy Agency.

4. Resolutions 574/2014/R/eel, 642/2014/R/eel, 360/2015/R/eel e 786/2016/R/eel.

5. However, this interpretation conflicts with Commission Regulation (EU) No 2016/631 of 14 April 2016, which, in regulating the scope of application relating to the regulation of generating groups, expressly states in Article 3(2)(d) that "This Regulation shall not apply to energy storage devices, with the exception of pumped storage generating groups".

6. Resolution of 23 December 2015, 654/2015/R/eel.

The content of this article is intended to provide a general guide to the subject matter. Specialist advice should be sought about your specific circumstances.

To print this article, all you need is to be registered on Mondaq.com.

Click to Login as an existing user or Register so you can print this article.

Authors
 
Some comments from our readers…
“The articles are extremely timely and highly applicable”
“I often find critical information not available elsewhere”
“As in-house counsel, Mondaq’s service is of great value”

Related Topics
 
Related Articles
 
Up-coming Events Search
Tools
Print
Font Size:
Translation
Channels
Mondaq on Twitter
 
Mondaq Sign Up
Gain free access to lawyers expertise from more than 250 countries.
 
Email Address
Company Name
Password
Confirm Password
Country
Position
Industry
Mondaq Newsalert
Select Topics
Select Regions
Registration (please scroll down to set your data preferences)

Mondaq Ltd requires you to register and provide information that personally identifies you, including your content preferences, for three primary purposes (full details of Mondaq’s use of your personal data can be found in our Privacy and Cookies Notice):

  • To allow you to personalize the Mondaq websites you are visiting to show content ("Content") relevant to your interests.
  • To enable features such as password reminder, news alerts, email a colleague, and linking from Mondaq (and its affiliate sites) to your website.
  • To produce demographic feedback for our content providers ("Contributors") who contribute Content for free for your use.

Mondaq hopes that our registered users will support us in maintaining our free to view business model by consenting to our use of your personal data as described below.

Mondaq has a "free to view" business model. Our services are paid for by Contributors in exchange for Mondaq providing them with access to information about who accesses their content. Once personal data is transferred to our Contributors they become a data controller of this personal data. They use it to measure the response that their articles are receiving, as a form of market research. They may also use it to provide Mondaq users with information about their products and services.

Details of each Contributor to which your personal data will be transferred is clearly stated within the Content that you access. For full details of how this Contributor will use your personal data, you should review the Contributor’s own Privacy Notice.

Please indicate your preference below:

Yes, I am happy to support Mondaq in maintaining its free to view business model by agreeing to allow Mondaq to share my personal data with Contributors whose Content I access
No, I do not want Mondaq to share my personal data with Contributors

Also please let us know whether you are happy to receive communications promoting products and services offered by Mondaq:

Yes, I am happy to received promotional communications from Mondaq
No, please do not send me promotional communications from Mondaq
Terms & Conditions

Mondaq.com (the Website) is owned and managed by Mondaq Ltd (Mondaq). Mondaq grants you a non-exclusive, revocable licence to access the Website and associated services, such as the Mondaq News Alerts (Services), subject to and in consideration of your compliance with the following terms and conditions of use (Terms). Your use of the Website and/or Services constitutes your agreement to the Terms. Mondaq may terminate your use of the Website and Services if you are in breach of these Terms or if Mondaq decides to terminate the licence granted hereunder for any reason whatsoever.

Use of www.mondaq.com

To Use Mondaq.com you must be: eighteen (18) years old or over; legally capable of entering into binding contracts; and not in any way prohibited by the applicable law to enter into these Terms in the jurisdiction which you are currently located.

You may use the Website as an unregistered user, however, you are required to register as a user if you wish to read the full text of the Content or to receive the Services.

You may not modify, publish, transmit, transfer or sell, reproduce, create derivative works from, distribute, perform, link, display, or in any way exploit any of the Content, in whole or in part, except as expressly permitted in these Terms or with the prior written consent of Mondaq. You may not use electronic or other means to extract details or information from the Content. Nor shall you extract information about users or Contributors in order to offer them any services or products.

In your use of the Website and/or Services you shall: comply with all applicable laws, regulations, directives and legislations which apply to your Use of the Website and/or Services in whatever country you are physically located including without limitation any and all consumer law, export control laws and regulations; provide to us true, correct and accurate information and promptly inform us in the event that any information that you have provided to us changes or becomes inaccurate; notify Mondaq immediately of any circumstances where you have reason to believe that any Intellectual Property Rights or any other rights of any third party may have been infringed; co-operate with reasonable security or other checks or requests for information made by Mondaq from time to time; and at all times be fully liable for the breach of any of these Terms by a third party using your login details to access the Website and/or Services

however, you shall not: do anything likely to impair, interfere with or damage or cause harm or distress to any persons, or the network; do anything that will infringe any Intellectual Property Rights or other rights of Mondaq or any third party; or use the Website, Services and/or Content otherwise than in accordance with these Terms; use any trade marks or service marks of Mondaq or the Contributors, or do anything which may be seen to take unfair advantage of the reputation and goodwill of Mondaq or the Contributors, or the Website, Services and/or Content.

Mondaq reserves the right, in its sole discretion, to take any action that it deems necessary and appropriate in the event it considers that there is a breach or threatened breach of the Terms.

Mondaq’s Rights and Obligations

Unless otherwise expressly set out to the contrary, nothing in these Terms shall serve to transfer from Mondaq to you, any Intellectual Property Rights owned by and/or licensed to Mondaq and all rights, title and interest in and to such Intellectual Property Rights will remain exclusively with Mondaq and/or its licensors.

Mondaq shall use its reasonable endeavours to make the Website and Services available to you at all times, but we cannot guarantee an uninterrupted and fault free service.

Mondaq reserves the right to make changes to the services and/or the Website or part thereof, from time to time, and we may add, remove, modify and/or vary any elements of features and functionalities of the Website or the services.

Mondaq also reserves the right from time to time to monitor your Use of the Website and/or services.

Disclaimer

The Content is general information only. It is not intended to constitute legal advice or seek to be the complete and comprehensive statement of the law, nor is it intended to address your specific requirements or provide advice on which reliance should be placed. Mondaq and/or its Contributors and other suppliers make no representations about the suitability of the information contained in the Content for any purpose. All Content provided "as is" without warranty of any kind. Mondaq and/or its Contributors and other suppliers hereby exclude and disclaim all representations, warranties or guarantees with regard to the Content, including all implied warranties and conditions of merchantability, fitness for a particular purpose, title and non-infringement. To the maximum extent permitted by law, Mondaq expressly excludes all representations, warranties, obligations, and liabilities arising out of or in connection with all Content. In no event shall Mondaq and/or its respective suppliers be liable for any special, indirect or consequential damages or any damages whatsoever resulting from loss of use, data or profits, whether in an action of contract, negligence or other tortious action, arising out of or in connection with the use of the Content or performance of Mondaq’s Services.

General

Mondaq may alter or amend these Terms by amending them on the Website. By continuing to Use the Services and/or the Website after such amendment, you will be deemed to have accepted any amendment to these Terms.

These Terms shall be governed by and construed in accordance with the laws of England and Wales and you irrevocably submit to the exclusive jurisdiction of the courts of England and Wales to settle any dispute which may arise out of or in connection with these Terms. If you live outside the United Kingdom, English law shall apply only to the extent that English law shall not deprive you of any legal protection accorded in accordance with the law of the place where you are habitually resident ("Local Law"). In the event English law deprives you of any legal protection which is accorded to you under Local Law, then these terms shall be governed by Local Law and any dispute or claim arising out of or in connection with these Terms shall be subject to the non-exclusive jurisdiction of the courts where you are habitually resident.

You may print and keep a copy of these Terms, which form the entire agreement between you and Mondaq and supersede any other communications or advertising in respect of the Service and/or the Website.

No delay in exercising or non-exercise by you and/or Mondaq of any of its rights under or in connection with these Terms shall operate as a waiver or release of each of your or Mondaq’s right. Rather, any such waiver or release must be specifically granted in writing signed by the party granting it.

If any part of these Terms is held unenforceable, that part shall be enforced to the maximum extent permissible so as to give effect to the intent of the parties, and the Terms shall continue in full force and effect.

Mondaq shall not incur any liability to you on account of any loss or damage resulting from any delay or failure to perform all or any part of these Terms if such delay or failure is caused, in whole or in part, by events, occurrences, or causes beyond the control of Mondaq. Such events, occurrences or causes will include, without limitation, acts of God, strikes, lockouts, server and network failure, riots, acts of war, earthquakes, fire and explosions.

By clicking Register you state you have read and agree to our Terms and Conditions